As of HyperX version 2026.2.14, Analysis Modifiers and Analysis Modifier Sequences were added to provide an additional layer of analysis customization. They do not write margins themselves, instead they control the inputs to criteria which write margins and the order in which those criteria are assessed. Some potential use-cases for Analysis Modifiers include machining tolerances, postbuckling, and strain life fatigue.
This page uses a machining tolerance example where as-sized thicknesses need to account for tight and loose tolerance machining. To ensure the margins report the worst-case scenario per-Zone, the Analysis Modifier adjusts the thickness prior to writing margins for selected Failure Modes.
Note
HyperX Analysis Modifiers provide a simple and modular way to control the flow of analysis by controlling criteria inputs.
Analysis Modifiers can be installed and managed similarly to Packages by using the Package Manager. As of HyperX version 2026.2.14, the Machining Tolerance Analysis Modifier is included with the install. To install an Analysis Modifier, locate it in the Package Manager and click "Install".
Analysis Modifiers are assigned to Analysis Properties via Analysis Modifier Sequences. An Analysis Modifier Sequence can contain one or more Analysis Modifiers which can be re-ordered within the sequence. Analysis Properties can contain multiple Analysis Modifier Sequences or none at all (matching how all Analysis Properties worked pre-2026.2.14).
Note
Analysis Modifiers and Analysis Modifier Sequences are Database-level entities that can be found and managed in the Library. That means they can be used and re-used on numerous Analysis Properties and edits in one place are automatically propagated to everywhere they are used.
The typical place to create and use Analysis Modifiers and Sequences is on the Analysis Property form. First, click on "Analysis Modifier Sequences" button and select "Create New" or "Add Existing" if you already have Analysis Modifier Sequences defined.
This adds a new Analysis Modifier Sequence to the Analysis Property where we can now add Analysis Modifiers by:
-
Select the Analysis Modifier Sequence.
-
Name it according to the type of criteria modification.
-
Click "Create a new Analysis Modifier".
-
Select an Analysis Modifier category from the list.
-
Click "Next" to open the Analysis Modifier form where you can define the values for this type of Analysis Modifier.
On the Analysis Modifier form, you can:
-
Read the documentation and changelog for this Analysis Modifier.
-
Set values for this Analysis Modifier's settings.
-
Optionally, link settings to Attributes which can override a setting's value across various entities.
Clicking "Apply" will save this Analysis Modifier and add it to the Analysis Modifier Sequence. On the Analysis Property form, you can add more modifiers to the current sequence by repeating the above process. You can now also use the "Modifier Settings" tab to quickly change the settings for each Analysis Modifier in this sequence.
When satisfied with the setup, add Solver-enabled Failure Modes to this Analysis Modifier Sequence. The Analysis Modifiers in this sequence alter the inputs to the criteria defined in these Failure Modes. In this case, the machining tolerance thickness adjustments we set will modify the corresponding values for the Metal Strength Failure Mode. Click "Apply" on the Analysis Property form to save all changes.
You can have multiple Analysis Modifier Sequences on an Analysis Property, and they can be in any order on the form. In the case of this example, different tolerance rules are applied to different Failure Modes using separate Analysis Modifier Sequences (see image below).
Multiple Analysis Modifiers can be added to an Analysis Modifier Sequence where their order within the Sequence impacts how they modify criteria inputs. They can be re-ordered by dragging and dropping on the "Sequence" tab. In the image above, the “Strength + Temp Sequence” modifies the thickness inputs based on the tolerance rules and then changes the analysis temperature for strength analysis. Separate Sequences do not impact each other, so the “Stability Sequence” would not use the temperature override from the other Sequence.
Once the Analysis Property is assigned, run Sizing/Analysis and review the Analysis Detail Report. Each applied Analysis Modifier will add a new section to the report showing effected inputs and their modified values.
Both Analysis Modifiers and Analysis Modifier Sequences are Database-level entities which are accessible in the Library. That way they can be assigned to numerous Analysis Properties and, if modified, those updates will automatically apply to wherever the Analysis Modifier and/or Sequences have been assigned.
To open the Library form for each of these entities, right-click the respective node in the Library and select "Show". From these forms you can create, edit, and delete these entities. The create and edit forms for Analysis Modifier Sequences and Analysis Modifiers follow the same form and function as the Analysis Property "Sequence" and "Modifier Setting" tabs, respectively. Deleting an entity from these forms will automatically remove it from anywhere it is assigned throughout the Project.