With the introduction of Solver Criteria, we've also introduced Sample Calculations (Sample Calcs) to provide a sense of how a method operates without having to set up every entity in the UI. Simply specify the inputs for a method and click calculate to see relevant intermediate values and margin of safety for the given inputs.
Tip
Sample Calculations allow a "back of the napkin" assessment for a given criterion. You can quickly get a sense of how a method works without having to fully set up and size a model.
As of HyperX version 2026.2.14, Sample Calcs are available for almost all native Solver criteria (see Sample Calculation Support for exceptions). Sample Calcs can be accessed for supported Solver Criteria from Failure Modes and/or the Analysis Watch Window. These can be used in two different Sample Calculation workflows, described below.
The quickest and simplest way to view Sample Calcs is via Solver-enabled Failure Modes (see "Project Setup" here). You can open one from the Library or create one using the "Create Package Failure Mode" button on the Analysis tab of the Ribbon.
From the Failure Mode form, look for the "Open Sample Calculation" button (with a ruler icon) on supported criteria.
Click the button for the criterion you want to test. That will open the Sample Calculations form for that Criterion. Naturally, the forms for various criteria will differ based on what inputs and methods are used for that criterion.
There are four main sections of this form:
-
Basic Information - At the top you will find the criterion's name, reference id (AID), and a description. There are also options to view documentation for this failure criteria and export the current values for this form to Excel.
-
Inputs - Here you will find the various inputs for the criterion.
-
Result - This section contains the Margin of Safety and relevant intermediate values.
-
MS and Basic Controls - The Margin of Safety based on the latest calculation is always visible. This section also features buttons to reset values to defaults, re-calculate values based on current inputs, and close the form.
You can find more information on the inputs and results values and equations by reviewing this criterion's documentation. You can find that by clicking the "DOC" button on the Failure Mode or selecting "Criterion Documentation..." after right-clicking in the Analysis Watch Window.
As of HyperX version 2026.1.13, you can access the criterion's documentation directly from the Sample Calculation form.
Changing one or more of the inputs and pressing "Calculate" will recalculate the values in the "Result" section.
You can reset individual values to their defaults by pressing the reset button corresponding to that field. Hovering over that button will also provide more information on what Analysis Details the field relates to and the default value. You can reset all input values by pressing the "Default" button at the bottom of the form.
You can launch Sample Calculations from the Analysis Watch Window and, in this case, the inputs values will be pre-populated with the corresponding values from the selected Zone.
To get started, first select a Zone, right-click, and select "Analysis Results".
In the Analysis Watch Window, results for Solver Criteria are shaded. Select one of those shaded cells, right-click, and choose "Sample Calculation...".
The form has the same general layout as before but with two key differences. The first is that the associated Zone ID is included under the reference ID near the top of the form. The second is that the values are based on the analysis results (if you were to open the Analysis Detail Report for this Zone, you would find these values there). These will be the "default" values to reset to once you start making changes.
Like before, you can edit input values and press "Calculate" to see the effect on the results. The only difference here is that the starting values are based on your model's current setup making them a much more realistic starting point for tinkering.
Tip
Using Sample Calcs in this way allows you to quickly try new values to understand what's driving the margin calculation. This lets you "look before you leap" into updating your model and/or design.