HyperX Solver is currently in an initial, limited release phase and doesn't yet support everything supported by the Standard methods. Results from supported Solver methods should generally match those from Standard methods for the same inputs (though there are some differences in certain cases). If you attempt to use Solver methods with settings/inputs that are not currently supported, HyperX will warn you and provide some information on what settings/inputs are unsupported.
Important
While we continue to roll out Solver methods please note that there may be some bugs or instabilities and results should be verified before they are used for production. We greatly appreciate feedback so please let us know if you experience any issues while using HyperX Solver.
As of its initial release in HyperX version 2025.1.4, Solver supports many commonly used features and methods. Those are:
-
Most smeared and unstiffened panel concepts.
-
Most beam concepts.
-
All load processing approaches.
-
Most standard criteria (see articles in the "Theory" category for more information).
-
Temperature-dependent Material properties, allowables, and most Correction Factors.
-
Batch processes like HyperFEA, HyperXpert, and Batch Runner.
-
Write custom criteria in C# (formerly known as Analysis Plugins).
As of HyperX version 2026.1.13, more features and methods are supported:
-
Ply-based composite ply property Correction Factors.
-
Windows and Linux HPC integration via Remote Solver. More information available upon request.
-
Convex Hull Load Processing Technique.
-
Several additional native Failure Criteria.
-
Custom Criterion API. For a full reference see:
As of HyperX version 2026.2.14, even more features and methods are supported:
-
Highly customizable Detailed Stress Reports featuring customizable Report Blocks.
-
Custom metadata management via Attributes.
-
Portable and customizable analysis processes in the form of Analysis Modifiers and Analysis Modifier Sequences.
-
Merge Output Databases.
-
Toggleable End A/B moments (Separate, Average, Max Magnitude) for beam loads.
-
Analysis Details can now declare display factors.
-
Improved performance across numerous processes.
-
Expanded Sample Calc support to nearly all native critieria.
There are some new settings introduced for HyperX Solver. There are also a few procedural differences between Solver and Standard methods that you should be aware of. Those are:
-
Multi-threading - Solver supports multi-threading. You can specify the numbers of threads to use via Project Run Settings.
-
Solver Failure Modes - If you use Standard Failure Modes, it will be easier to switch between Standard and Solver Sizing/Analysis. Solver Failure Modes (available via Packages) have additional features such as added settings, versioned HMEs, changelogs, and Sample Calculations.
To create a Solver Failure Mode, click "Create Package Failure Mode" on the Analysis tab of the Ribbon and select the type of Failure Mode from the popup.
-
Layup Balance - Solver considers balance for fabric laminates when evaluating Layup Rules, whereas the Standard analysis ignores it.
-
Returned Non-Viable Candidates - In a situation where there are no Viable Candidates, i.e. no candidates that have positive MS and satisfy design constraints (such as Layup Rules, R ratios, and geometric feasibility), Solver and the Standard Engine may return different candidates. With Standard Sizing, you may get a -MS candidate (that otherwise satisfies design constraints) whereas Solver may return a candidate that violates design constraints but has +MS. In 2026.1.13, Solver will provide a warning to the Process Monitor when this happens.
-
Peak Load Reversal - When using Peak Loads if there's a load reversal in a panel, Solver only considers the compression-compression region, and the Standard Engine analysis will consider both the compression-compression region as well as the compression-tension region.
-
Hidden Grid-Stiffened Geometry Checks - The Standard Sizing Engine has several hidden geometry checks that filter out grid-stiffened concepts with highly different thickness and spacing (etc.) between webs. Solver does not have these checks, which means Solver will sometimes pick candidates Standard Sizing rejects. You can disable these checks in Standard Sizing with the Advanced Setting: "Grid Stiffened - Use default stiffener geometry checks".
-
Beam Reference Position - Solver considers the original offset in the FEM as well as the user-selected reference position when applying beam loads (and shifting them) to beams. The Standard Sizing Engine always applies loads at the centroid. This should resolve with FEA iteration but will cause divergences in initial results if Analyzing/Sizing a case that does not exactly match the FEM.
-
Thermal load combinations with average/statistical - When combining mechanical and thermal loads, Solver first computes the per-element combined load. Then it finds the tension/compression average of this load. The Standard Engine first does a tension/compression average of the individual subcases, before combining them. It's basically the difference between AVG(X+Y) and AVG(X)+AVG(Y) with different subsets of elements due to load reversals.
-
Beam Loads Applied to Panels - Solver uses panel y-span instead of spacing to convert to running loads. It also assumes zero curvature for \(\kappa_y\) and \(\kappa_{xy}\), whereas the Standard Engine allows anticlastic bending.
-
Moment and B Term Sign Convention - Solver uses "textbook" sign convention for CLT which means moments and B terms will generally be negative values of what is seen for the Standard Engine.
Sample Calculations are supported for almost all native Solver criteria. The native Failure Modes and criteria that do not support Sample Calcs as of HyperX version 2026.2.14:
-
Geometry
-
No Geometry criteria support Sample Calcs
-
-
Ply Based
-
Composite, OHT
-
Composite, OHC
-
Due to procedural differences in Solver algorithms compared to Standard versions, there are some cases where margin calculations are known to differ between the two. Those are:
-
Orthogrid Local Buckling - Missing (not on by default) correction factors for pockets.
-
Hat Panels - Known differences in stiffness formulation; expect different margins.
-
Panel Buckling - Solver does not compute adjusted compression span; expect different margins.
Note
You can switch the Standard analysis to use this Solver behavior with Advanced Settings.
-
Composite Crippling - Solver does not support the mode where the controlling strength margins are used to derive FcuAxial. Users should pick a specific criterion instead.
-
Miscellaneous Advanced Settings - There are many Advanced Settings that impact Sizing/Analysis on the Standard Engine which have not been integrated into Solver. Please contact us if you rely on one that is not yet supported.
-
FEA Loads - Solver transforms loads into a consistent coordinate system, rather than assuming they are all aligned. This can cause differences with Standard analysis for aggregating load processing approaches (.e. average, statistical) if the material directions are not parallel within a Zone.
Note
There is an Advanced Setting ("Solver rotate element loads into zone coordinates" set to "No") to revert Solver behavior back to the non-rotated version.
-
Analysis Detail Units -Not all engineering units and display factors are represented in Solver Analysis Detail Reports.
-
Johnson-Euler Interaction - Johnson-Euler is an interaction between crippling and buckling. Solver consistently evaluates both crippling and buckling using the same loads before interacting, whereas the Standard Sizing uses averaged loads for buckling but local strength loads for crippling and then combines them. The Solver approach to evaluate buckling with local element-based loads may be significantly more conservative.
We've added a new Advanced Setting to force Standard methods to match their Solver counterparts. To enable it:
Enabling this setting has the following effects:
As of HyperX version 2026.2.14, HyperX Solver does not support the following features, methods, and settings. As more features are added in subsequent releases, check back here to see which of these features have become available.
-
Most Advanced Settings other than "use average tension/compression" and "use room temperature average tension/compression" (Contact us if you rely on one that is not yet implemented)
-
Technique 3 and Grid pattern Discretely Stiffened Models
-
Advanced analysis routines such as postbuckling, beam-column, and superimposed pressure
-
Calculation of thermally-induced stresses (delta T)
-
Polynomial laminate allowable curve definitions
-
Certain concepts: Circular beam, grid other than orthogrid/isogrid, continuous flange concepts, composite grid stiffened, composite cruciform.
-
Certain Failure Modes: stiffener-skin bonded strength and temperature
-
Certain Criteria: sandwich concentrated crushing, LaRC03, Puck, NACA postbuckling, fatigue, triaxiality, LTV crippling, forced crippling, Levy flexural-torsional stiffener buckling, beam flexural-torsional buckling.
-
Solver can't be used with Standard Analysis Plugins (contact us for help with these)
-
Through-thickness temperature gradients
-
For Design Case Overrides, Solver does not generate the Filtered Load Case list (but can apply specified list if provided).
-
Variable Fiber Directions
Tip
Run Standard Sizing/Analysis on the same Zones at any time to compare results if desired.
While in this initial release window, feedback on Solver is especially welcome! We'd love to hear what works well for you and what doesn't. We also want to hear what you'd like to see Solver handle next so that we can prioritize Solver development to better suit your needs. Please reach out with any and all feedback/requests!