The Project Run Settings form is used to define how to run single and batch operations in HyperX.
For "Single Runs", choose which Sizing/Analysis Engine to use: Standard or Solver. For "Batch Runs", choose to use the same option used for Single Runs or Remote Solver.
Compared to the Standard Sizing/Analysis Engine, Solver includes additional features related to multi-threading, saving outputs, and more. These can be accessed, edited, and saved for all HyperX Projects in this Database using the buttons at the top of this form.
Thread Count Settings
You can set the maximum number of threads to use for general Solver processes using this form. The more threads you use, the more tokens are required for each process which can be seen on the Thread Count Settings form. Click "Token Availability" to check the remaining balance of tokens for your organization's license.
General Solver Settings
Solver exposes several settings that allow you to change how much output data they have, particularly for Analysis Results and Details.
Analysis Results
-
Load Scenario Limit - This setting specifies how many analysis results to return per-criterion per-Zone. When set to 1, it means you will get the most critical result for each criterion and Zone (effectively matching the results of Standard Sizing/Analysis), and higher values will return the next most-critical results in order.
Note
Load Scenario is a new term for HyperX introduced with Solver to describe the relationship between loads and analysis criteria within a Zone.
A single Zone is associated with one or many Load Scenarios, depending on the Zone’s Load Property. Non-FEA Load Properties have one Load Scenario per row. For FEA-based Load Properties, it can be useful to think of Load Scenarios as approximately paired with Design Load Cases, though this is not the case for all Load Properties.
-
Load Scenario Limit Type - This setting affects how the numerical Load Scenario Limit (above) is interpreted. When doing element-based analysis and set to "Per Element", it means that each criterion will get n (where n = limit value set above) analysis results per criterion per element. When set to "Per Entity", it means that each criterion will get the top n (where n = limit value set above) results overall, and it would not be guaranteed that every element has a stored result for every criterion.
Note
In the event that the criterion is not element-based (e.g. panel buckling), or the Load Property is not element-based (e.g. statistical), then this setting has no effect (behavior is the same as being set to "Per Entity").
-
Results - This setting determines whether you want results (margins) for all candidates, or just the optimal. The primary place that non-optimal candidate margins show up is in the Design Result form when Sizing with multiple requested candidates.
-
Details - This setting determines whether the results you generate should also contain Analysis Details. "None" produces smaller output files and faster runtimes, but "Optimal Candidate" is the most common choice. "All Candidates" should be avoided in most cases as there is no mechanism to view details for non-optimum candidates in HyperX as of version 2026.1.13.
-
Report Per-Element Details - This setting determines whether to report Analysis Details for all element-based results, or just the critical one on a per-criterion basis.
Note
This setting does not determine which results are returned like the others. It only affects which details for those results are included.
Echo Input Data - As of version 2026.1.13, these settings are currently unused.
Cache
-
FEA Loads Cache Limit (GB) - The maximum size (in gigabytes) of FEA Loads data that can be cached in memory (RAM) during Sizing/Analysis.
Tip
Provided the RAM is available, increasing this value for models with large amounts of HFN data may result in significant performance improvements.
-
Section Table Cache Limit (GB) - The maximum size (in gigabytes) of Section Table data to cache in memory during Sizing. For efficiency, Solver only computes the candidates in a Section Table one time per design and shares it between all Zones using that Design Property. However, when a Sizing problem includes many Design Properties with large Section Tables (millions of candidates) the amount of RAM consumed may be very large and grow over time.
Tip
Provided the RAM is available, increasing this value for runs with large Section Tables may result in significant performance improvements.
Output
-
Output Mode - Controls the Solver Database (SDB) output mode.
-
Overwrite - (Default) Most similar to Standard Sizing Engine behavior. One Zone will only have one result at a time, which is overwritten by subsequent runs.
-
Append - Creates a new set of results in the SDB for each run, meaning that one Zone can have an indefinite number of sets of results. This opens up interesting opportunities for results comparison but also presents an organizational challenge where SDB file size can grow rapidly if not employed carefully.
-
DSM Sizing
-
DSM Sizing Approach - Allows users to pick from one of several experimental sizing algorithms for DSM.
Tip
The default "Reconciled Skin" approach produces the lightest weight results and is recommended for use in most cases. These other approaches may be useful in situations where reducing processing time or increasing manufacturability are more important than overall weight of the design.
-
Reconciled Skin (Default) - This algorithm does not group Panel Segments and sizes each one individually (comparable to the Standard Sizing Engine approach). This approach typically produces the lightest results and is recommended in most cases.
-
Grouping - Arbitrarily groups 3-4 connected Panel Segments to find the shared skin design that results in the lowest overall weight for the panel group. Compared to sizing each Panel Segment separately, this algorithm produces more manufacturable designs in less time while only being slightly heavier.
-
Breadth First - Similar to the Grouping algorithm but makes assumptions on how to group Panel Segments more optimally. It produces results that are comparable to the Grouping algorithm in weight but with a faster processing time.
-
Greedy - Groups Panel Segments together along panel bays based on similar loads they experience. This algorithm is even faster than Breadth First and tends to produce lighter and more manufacturable designs.
-
Greedier - Extends the Greedy algorithm to allow grouping Panel Segments across panel bays (horizontally) in addition to grouping along panel bays (vertically). This can produce lighter, more manufacturable designs in less time than the Greedy algorithm but usually requires a lower Greedy DSM Threshold to attain those results.
-
-
Outer Skin Assumption - For skins with only one attached stringer, define whether the outer skin elements are assumed to represent the entire attached skin or only half.
-
Greedy DSM Threshold - (For Greedy and Greedier DSM algorithm only) This parameter controls how aggressively it groups skin bays to force them to have identical sizing results.
Licensing
-
Token Queueing Mode - Define the behavior Solver should attempt when a requested operation would exceed remaining token count.
-
Immediately exit if insufficient tokens are available - Cancel the operation and notify the user
-
Queue indefinitely for the specified token count - Add the operation to a queue that will process once more tokens are made available.
-
Runs at a lower token count, if possible - Attempt the operation in a way the would require less tokens. For instance, trying to run the operation at a lower thread count.
-